Sprinkler and suppression
Wet pipe, dry pipe, pre-action, and deluge sprinkler systems for commercial, industrial, and cold-store environments. Designed and installed to AS 2118, from hydraulic calculation through to witness testing.
We design, install, and maintain fire protection systems across commercial, healthcare, infrastructure, and industrial buildings. Every system is delivered against the Australian Standard that governs it, and every building under our maintenance agreements carries the records to prove it.
We work across the fire protection systems required on a modern commercial or institutional building, from wet and dry suppression through to detection, alarm, and hydrant infrastructure. Each system is designed, installed, and commissioned by the same team that maintains it.
Wet pipe, dry pipe, pre-action, and deluge sprinkler systems for commercial, industrial, and cold-store environments. Designed and installed to AS 2118, from hydraulic calculation through to witness testing.
Addressable fire detection, aspirated smoke detection, fire indicator panels, and emergency warning systems for complex multi-zone buildings. Delivered against AS 1670 and integrated with the building's wider services.
External hydrant networks, internal hose reels, booster assemblies, and fire pump sets for new buildings and upgrades to existing ones. Designed to AS 2419, coordinated with the hydraulic services scope under a single contract.
Clean agent and inert gas suppression for data centres, switchrooms, heritage interiors, and other areas where water-based systems are unsuitable. Specified, installed, and commissioned to AS 4214 and NFPA 2001.
Fire protection in Australia is a regulated field. The table below sets out the primary standards that apply to the systems we install and maintain, the buildings they apply to, and the inspection cadence expected under AS 1851.
| Standard | Application | Inspection cadence |
|---|---|---|
| AS 1851 | Routine service of installed fire protection systems across all building classes. Sets the framework for inspection, testing, and defect reporting used in every Annual Fire Safety Statement. | Monthly, quarterly, six monthly, and annual routines depending on system. |
| AS 2118 | Design and installation of automatic fire sprinkler systems, including wet pipe, dry pipe, pre-action, and deluge configurations. | Six monthly routine, annual full inspection under AS 1851. |
| AS 2419 | Design and installation of fire hydrant and hose reel systems, including booster assemblies and pump sets. | Quarterly routine, annual flow and pressure testing under AS 1851. |
| AS 1670 | Design, installation, and commissioning of fire detection, alarm, and emergency warning systems, including addressable detection and EWIS. | Monthly visual routine, annual full functional test under AS 1851. |
Every practitioner who signs a compliance document on our behalf holds the accreditation required for that signature. The list below reflects the credentials held by the fire services division, recorded in our prequalification pack and available to clients on request.
Fire Protection Accreditation Scheme practitioners across sprinkler, detection, hydrant, and special hazards system classes. Current across New South Wales under the signing authority required for annual fire safety statements.
Third-party certified quality management system covering design, installation, commissioning, and maintenance activities across the fire services division.
Third-party certified occupational health and safety management system, aligned with the expectations of tier one head contractors and public sector clients.
Plumbing, mechanical, and fire protection licences held in every state and territory we operate in, including New South Wales, Victoria, Queensland, Western Australia, and the Northern Territory.
A small sample of the buildings where Axis has delivered fire protection scope, either as the specialist fire subcontractor or as part of an integrated building services package.

Sprinkler, detection, and hydrant scope delivered alongside hydraulic and medical gas services on one of New South Wales' largest teaching hospitals. Coordinated with the head contractor's clinical commissioning programme.
Healthcare · Sydney, NSW

Integrated fire protection package across the Barangaroo hotel and residential tower, covering sprinkler, EWIS, detection, and hydrant systems from basement plant rooms through to guest-facing floors.
Hospitality · Sydney, NSW

Specialist deluge and suppression works on one of Australia's largest resources projects, delivered to the programme and documentation standards of the lead contractor and the site's hazardous area classification.
Resources and energy · Darwin, NT
We are happy to walk through scope, standards, and where Axis might fit alongside your existing consultants and head contractor. A short conversation is usually the best place to begin.